Overview of Shortcut Keys

15 Dec 2022 admin In 1gal

Looking for:

Eplan electric p8 shortcut keys free

Click here to Download

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
You can tell this by the fact that in the Page range group box, the Entire project option is not activated. Place the legend on the panel layout page.
 
 

 

Eplan electric p8 shortcut keys free

 

Thank you in advance. Can someone upload EEC One 2. With best regards! Thanks Gemmotor! Will it not affect the functionality of the “license”? The window is dockable and has its own standard Windows buttons. In a “maximized” view, the window of the editor fits into the main window in such a way that the title bar is integrated into the menu bar of the main window see also the illustration on page In the “minimized” view, the window has its own title bar.

The Page type field is automatically prepopulated with Schematic multi-line I. In the Page description field, enter the text, Power supply. Any page or structure level may be selected when you do this. Note: Based on the Beginner mode selected in the Select scope of menu dialog, you use fields that allow multilingual entries e.

This function provides you with the whole word based on the letters you type in. Only words in the dictionary will be suggested. In the tree view of the Page navigator, select the 1 Power supply page. Most property fields already have values. EPLAN accepts the properties of the selected page and automatically suggests the next free page for the Full page name.

Click on [Clear fields]. The automatically suggested Full page name and the prepopulated Page type are kept. Next to the Page type field, click the [ In the Page description field, enter the text Cover sheet.

For the Form name property, click in the Value field next to it, and then click the button that appears. The plot frame used for a page is already predefined in the project settings.

The other displayed properties, Scale and Grid, are already prepopulated with correct entries. Then, in the Page type field, select the entry, Schematic multi-line I , and in the Page description field enter the text, Control ET1.

Now you have created the pages you need for editing the schematic. Closing a page Since you don’t immediately need the second schematic page, close it again. In the tree view of the Page navigator, select the page 2 Cover sheet. The cover sheet of the project is shown. This is the case, if in the View menu, you activated the menu item Workbook. Tip: To open a page selected in the Page navigator, you can also doubleclick on the page or press the [Enter] key.

Open the page 1 in the same way. This will automatically close the first page and display the empty schematic in the Graphical editor. For instance, select page 2 again, then from the popup menu of the Page navigator select the menu item Open in new window. For every opened page, a tab is shown below the graphical editor window.

You can quickly switch between pages by clicking these tabs. The pages created, however, don’t yet have structure identifiers. In the following section, we describe how you can assign the identifier by editing the page properties. In the tree view of the Page navigator, select the cover sheet page 2 Cover sheet. Change the value in the Full page name field.

Here, you can enter the structure identifier and the name of the page e. Enter the value ANL in the Higher-level function field. Enter the value DBT in the Mounting location field. In the Page name field, change the entry from 2 to 1. The structure identifiers are accepted for the field of the same name in the Page properties dialog.

In the Page properties dialog, click [OK]. For the “Higher-level function” structure idenwill be used; and for the tifier level with the identifier ANL, the icon “Mounting location” level with the identifier DBT, the icon will be used. Repeat this action for the schematic page page 1 and 3.

In the Full page name dialog, as the structure identifier for the Higher-level function, enter the designation ANL again. For the Mounting location, enter the designation SCP for the schematic pages. And for the second schematic page, in the Page name field, change the entry from 3 to 2. Now all pages in the project have structure identifiers.

You may first have to enlarge the Page navigator window a little before you can read all the page descriptions. Note: If you have made a change during page editing for instance, changed page properties, inserted graphical elements, etc. There is no separate save necessary, and so there is no corresponding menu item in the program!

You will also learn how to open and close a project, and you will learn a few basic commands for viewing and editing a project. Opening a Project 1. Here, the projects are shown which are located in your predefined project directory by default.

Click [Open]. Then repeat this for the plus sign in front of the structure level CA1, then for the next to the structure level EAA. The pages are now displayed in the “lowest” project level. First, page through the pages of this extensive project. The currently selected level in the tree view will be opened or closed. A minus sign before a level indicates that the level is already open.

For instance, if you want to show all the pages of a project in the tree at once, then select the closed level with the project name, and press the [X] key on the numeric block of your keyboard.

For a larger project, this process can take some time. Paging Through the Project Pages Using the appropriate program functions, you can look at the pages of a project one after the other in the Graphical editor. Repeat this action a few times and look at the contents of the pages in the Graphical editor. If the tree structure in the Page navigator was not yet completely opened, this will be done while paging through the pages. The page name and the description of the currently opened page are highlighted in bold in the Page navigator.

Page back a few pages, too. However, if your cursor is located in the Page navigator, the keys will not page through the pages but will cause the cursor to jump to the bottom or top page shown in the tree view.

Turning on the grid display A glance at the two menu items View and Options will show you that in EPLAN there are numerous program functions which make it easier for you to draw schematics.

You can work with a grid to make the positioning of elements easier. By default, in the Options menu, the menu item Snap to grid is activated. If this option is activated, the graphical elements and symbols are positioned directly on the grid points of the grid during the drawing process. The size of the grid used is stored as a page property. In the graphical editor, you can modify the grid size set by default to the respective page to buttons in the View toolbar, you can switch betype.

Using the tween five different grids, for which different grid sizes have been stored in the user settings. Please keep the Snap to grid option activated during the subsequent schematic generation and use Grid C with the default grid size 4. The grid size used is displayed in the status bar. The “ON” or “OFF” text in the status bar in front of the grid size indicates whether the snap to grid is activated or not see example regarding status bar on page View toolbar, click the The use of grid snap is independent of the grid display options.

If this view bothers you later when creating the schematic, then turn the grid display off in the same way. For schematic editing, it is often a good idea to enlarge a certain screen segment in order to be able to see details better.

For instance, you can use the “window zoom” in order to show a certain window segment in an enlarged view. Left-click the mouse in the upper left corner of the schematic, and use the mouse to open an area which includes about a quarter of the schematic page. Click the left mouse button again. By default, during scrolling the mouse wheel acts in the same way you are familiar with from other CAD programs.

In the settings, you also have the option of changing the scrolling behavior so that it matches the behavior of text editing programs. In this case, when you scroll with the mouse wheel, the visible section of the page is moved upwards or downwards. Move the mouse pointer onto the element with the designation -Q1. Below the symbol, a small text window Tooltip is displayed with information about the element. Select the element by clicking on it. The element -Q1 is completely deleted.

You can, however, use the Undo command to reinsert the element. Note: When editing elements in the Graphical editor, besides the usual Windows operating methods first select elements, then call command , in most cases the reverse order of operation first call the command, then select elements is also supported. Practice this once for the element -Q1 you just inserted. The box with the red X is the symbol assigned to the delete function, and the box with the dashed line stands for the area to be selected.

Left-click the mouse button on the upper left of the element, and use the mouse to drag a frame around -Q1. Closing a Project 1. If your cursor is in the Page navigator, then the project for which you have selected one or more pages is closed. Note: Please note that the menu item Close in the popup menu Page navigator only closes the page currently located in the foreground.

Tip: In the Project menu, beneath the menu item Print, a list of the last projects opened is displayed. You can use this list to open a corresponding project without needing to use the menu item Open. You have just closed the demo project. EPLAN opens the demo project again. After it opens, practice closing it again.

Now that you have looked at the complicated demo project in this chapter, in the next two main sections you will create a much “simpler” schematic. By default, symbols do not contain any logical data. These are generally stored in the functions. What is a component? A component is a graphical element for the representation of a function. It consists of the function and symbol. The function contains the logical data and the symbol contains the graphical data.

A component has a device tag, connection point designations, and so on. What are devices? Devices are logical electronic or fluid-technical units that work together. What are coordinate systems? Depending on the page type, a certain coordinate system will be the default. On electrical engineering schematic pages, the coordinate system is of the type, Electrical engineering. This has its origin in the upper left corner of the drawing surface.

The coordinates are indicated in grid increments RX and RY and displayed in the status bar. Angles and other elements T-nodes, interruption points, etc. In the Current cursor position group box, for X: enter 10 and for Y: enter The current cursor position is also shown in the bottom left corner of the status bar. You can immediately insert more angles. Tip: To call the Coordinate input quickly, you can also press the [P] key.

This kind of determination of insertion coordinates is not absolutely necessary when editing your own schematics. To do this when inserting — as described above — you can use Coordinate input or position the elements at the given coordinates using the mouse or the cursor keys. If you use the Coordinate input dialog to do this, each element is directly placed after confirming the coordinates with [OK].

If you position the element using the mouse or keyboard, then after positioning you must still left click or press [Enter] in order to place the element on the page. The grid size for pages of the type, Schematic multi-line, has a default of “4. If, for example, in the Page properties you changed the default Grid from “4. Once the connection points of two angle symbols are directly horizontally or vertically aligned in the schematic, they are automatically connected with a connection line.

This is called “autoconnecting”, in which the connection lines created this way are called “autoconnect lines”. Only these autoconnect lines are recognized and reported as electrical connections between symbols.

Insert element into search results list. Go to graphic. Print a project. Rotate graphic. Search function: Synchronize selection. Insert a path function text. Set options for placement of parts in 3D mounting layout navigator. Redo last step.

Undo last step. Close graphical editor. Create page macro. Switch between open windows, like the graphical editor, navigators, etc. Update reports. Jump left to the next insertion point. Jump right to the next insertion point. Jump up to the next insertion point. Jump down to the next insertion point. Insert linear dimension. Global editing: Edit data from report. To see the page properties, go to your page navigator, select a page, right click, properties.

Highlight the pages that you want to copy to another project. Right click and select COPY. In this manner, pages within a project can be renamed and thus moved. For automated allocation of page names, EPLAN suggests the next available page name in the target project. Subpages are automatically incremented. For DIN projects, the suggestion is group referenced.

You can either retain the suggested start page names, or change them. For several pages, you can also customize the increment defaults. To do that go to page, number Highlight the project.

Press ok if you accept the numbering numbered for you. The page types help to structure a project and accelerate the analysis processes, since non-relevant pages can be skipped. All page types behave the same way in the page navigator. Pages are basically either logic pages or graphical pages: On Logic pages the device data is analyzed and reported, and autoconnect lines are automatically generated.

This does not occur with Graphical pages; these are only used for displaying data or for drawing graphics but not schematics. The page types “Schematic multi-line”, “Schematic single-line”, “Fluid power schematic” and “Overview” are all logic pages, all other page types are graphical pages.

The page type is assigned when a page is created, but can be subsequently changed. When a page type is changed, all other page properties remain unchanged, the page is just analyzed and reported differently.

Specify the starting point of the line and click the left mouse button. Specify the end point of the line and click the left mouse button.

Specify the starting point of the polyline and click the left mouse button. Specify the next points of the polyline, and click with the left mouse button each of the points to place. Specify the starting point of the rectangle and click the left mouse button.

Pull the rectangle out in any direction, and click with the left mouse button to specify the end point. Define the center of the circle, and click the left mouse button. Pull the circle out from the center, and click the left mouse button to define the radius. Define the first point on the circle, and click the left mouse button. Define the second point on the circle, and click the left mouse button.

Define the third point on the circle, and click the left mouse button. Define the first point on the arc, and click the left mouse button. Define the second point on the arc, and click the left mouse button.

Pull the circle out from the center, and click the left mouse button to define the arc. Draw arcs and sectors Arcs can also be defined using the center or with three points on the circle. Sectors of circles are defined using the center.

Define the first point on the arc or sector, and click the left mouse button. Define the end point of the arc or sector, and click the left mouse button. Define the center of the ellipse, and click the left mouse button. Pull the ellipse out from the center, and click the left mouse button to define the size of the ellipse. They contain a multitude of information such as graphical elements, connection points, the assignment to a symbol group, the logic, etc.

The relationship between a symbol and a function can appear as follows: The symbol does not represent a function, such as an angle or a Tnode. The symbol represents a function, such as an NO contact or an NC contact. The symbol represents multiple functions, such as a motor overload switch or a triple fuse. The symbol represents part of a function, such as a device connection point or a change-over contact hook.

The symbol libraries are used to manage the symbols. A symbol library can contain an unlimited number of symbols. When editing a symbol only the changed symbol is opened and saved, not the entire symbol library. This minimizes the problems that could arise when multiple users are working in one library simultaneously.

Logical data is stored in the function definitions, graphical data in the symbols. This separation is significant when working with an engineering approach and offers a number of additional advantages for a modern CAE product such as standards independence.

EPLAN supports both a graphics-oriented drawing interface copy pages, add macros, place symbols, etc. If you work with the graphics-based interface you don’t need to worry about functions or function definitions. Function definitions are already assigned to the symbols in the standard symbol libraries. You simply place a symbol or a macro and the default assigned function definitions are automatically added.

If you work with the engineering interface or want to adapt reports, numbering, etc. It consists of a function and a symbol. The function contains the logical data and the symbol contains the graphical data. A component has a device tag, connection designations, and so on. They are inserted using symbol selection. They can be copied.

They can be deleted. They can be labeled, and the label can be formatted individually. They generate automatic connections autoconnecting. They are listed in the reports. The logic of the underlying function can be changed so that the device behaves differently e. Cross-references are detected automatically and can be displayed.

Dialogs contain different control elements depending on their program function and their specific use. Dockable dialogs The Page navigator, the device navigators and the Message management are “dockable” dialogs. Message and notification windows These dialogs inform you about particular settings or possible errors, or require you to answer a confirmation security question.

Subsequent dialogs Some dialogs cause a subsequent dialog to be displayed. Write-protected dialogs These dialogs contain data that can only be edited by users having specific access rights. A preview of the autoconnection lines is shown in the graphical editor, which shows where a connection from one symbol to another symbol is possible. As an extra aid for placement, a line is also shown between the first placed symbol and the current cursor position. This allows you to place symbols along a line.

Insertion points and connection points pointing in the same direction may not lie on top of each other. If this occurs when inserting a symbol then an error message is displayed and the action is cancelled. Exceptions to this are symbols containing opposing connections laid on top of each other at the same point, e.

The device numbering setting can be changed. It has the same value before and after a fuse in normal cases. The borders of a potential are defined by the source and the consumer. By default, physical potentials end at consumers, transformers or converters.

A potential terminal is drawn in the schematic in the same manner as a “normal” terminal. It is however, only characterized by the connection properties, since it is not a separate item e. All parts number are divided into different type of category. Only these autoconnect lines are recognized and reported as electrical connections between symbols. Autoconnecting is only active in schematic pages. By inserting connection symbols such as angles, T-nodes, double junctions, jumpers, and interruption points, you can influence the flow of automatic connections.

They represent the flow of connections and have no function definitions. The wiring model describes the logic within a symbol, that is, the connection points between which a connection flows. It is saved as a property on the symbol. It is a popular method of representing devices for which no symbol exists in a symbol library prescribed by the end customer.

Black boxes are used in various different ways:. For allocating device tags to terminals, since the terminal DT can’t be moved because otherwise the connection point designations would also be moved , e.

For special protection devices that cannot be represented using the normal symbols, but which must also display a contact image. The interruption point name can be the name of the logical potential. In the process, no distinction is made between source and target interruption point; the source and targets are automatically determined. An interruption point can be connected at both sides. If this is not desired, the connection can be inhibited by using a break point.

An interruption point with an open connection is therefore not an error. For this reason, the cross-reference must uniquely designate the page that is being searched. An orientation within the page is also required, the column. Since a column can also be relatively large, the row provides a further orientation within the page. In the Display group box, define how the cross-references to interruption points are to be displayed.

In the Separator group box, you define which character is to be used as a separator betweenPage and column as well as Row and column. Select the Display settings section. Insert angle down, right. Insert angle down, left. Update view “Redraw”. Insert angle up, left. Insert T-node down. Insert T-node right. Insert T-node left. Delete the contents of a window selection area. Move cursor to left edge of screen. Move cursor to right edge of screen. Insert device connection points. Insert interruption points.

Insert cable definition. Insert connection definition point.

 
 